Block electrolysis equipment is intended for getting disinfecting agent - sodium hypochlorite - by electrolysis of salt and water solution. Equipment is connected to the water supply and can be used for drinking water disinfection, disinfection of water supply systems at water treatment stations for disinfection of water in the pool, disinfection of wastewater, including biologically treated. And also, the obtained pure sodium hypochlorite can be metered and stored in a separate container and further future use for disinfection, sterilization or bleaching.
№ | Specifications |
Value
|
|||
---|---|---|---|---|---|
1 | Approximate volume of disinfected water, m3 / day: The groundwater Surface water Wastewater |
2500
1000 500 |
|||
2 | Performance of equipment on active chlorine kg/day |
2,5
|
|||
3
|
Specific costs of salt to 1 kg of active chlorine, kg | ~ 4,2 | |||
4
|
Concentration of active chlorine in hypochlorite solution, g/l |
7…8
|
|||
5 | Power consumption, kW | ~ 0,45 | |||
6 | Power supply | 220 V, 50 Hz | |||
7 | Quantity of cassettes | 1 | |||
8 | Term of work the cartridge electrodes, years | up to 5 | |||
9 | Overall dimensions *, width × depth × height, mm | 800 × 500 × 1200 | |||
10 | Mass of the equipment, kg | 45 | |||
11 | Number of attendants ** | 1 |
Notes: * The power supply is set so as to exclude the possibility of contact with moisture.
** Constant maintenance is required.
Electrolysis equipment operates on the principle of electrolysis of sodium chloride solution in the single cell. Generated during the electrolysis of sodium hypochlorite is continuously dosed into the treated water by gravity in a tank of clean water or sewers. The installation consists of node preparation of brine, the electrolyzer, power supply unit, a gas separator. The unit for preparing the salt solution comprises a plastic tank, and flow of the salt solution and water. The cell comprises an electrolysis chamber and placed it in the cassette electrodes. The separator for separating gas generated by electrolysis of sodium hypochlorite and removing them to the atmosphere.
Operating conditions must comply with GOST 15150-69, execution facilities UHL-4 (temperature from + 1 °C to + 35 °C, relative humidity 80% at + 25 °C). Installing Client goes off the shelf and installed by the Customer according to the instructions of the passport and the instruction manual.
Delivery conditions. Production time 30 working days from the date of prepayment of 50%. Acceptance of the electrolysis equipment carried out on the territory of the Contractor. Shipment - by self after 100% payment or shipping by the Carrier. Provides warranty (12 months) and post-warranty service. Installing arrive to the Customer in finished form and installed by the Customer according to the instructions of the passport and the operating instructions.