Carburizing furnace СГЦМ-13,5.15.3/10
| № | Specifications |
СГЦМ-13,5.15.3/10
|
|||
|---|---|---|---|---|---|
| 1 | Rated power, kW |
55 ±5
|
|||
|
2
|
Power supply | 3×380 V, 50 Hz | |||
|
3
|
Maximum temperature in the working space, ºС |
1000
|
|||
| 4 | Range of automatic temperature control , ºС | 40...1000 | |||
| 5 | Dimensions of working space, length × width × height, mm | 1350 × 1500 × 300 | |||
| 6 | Temperature stability in a steady thermal conditions without cages, °C, not worse | ± 3 | |||
| 7 | Atmosphere in the working space | Prepared gas | |||
| 8 | The unevenness of distribution of temperature in the furnace, in a steady thermal conditions, without cages, °C | ± 5 | |||
| 9 | Mark programmable temperature regulator / thermocouple type | ТРП-08-ТП (by default) / ТХА | |||
Carburizing is carried out in the bell-type furnace which comprises a heat resistant steel retort 8 mm thick. Karbjurizator - liquid hydrocarbons (kerosene, etc.) or carburizing gas (endogas). The gas pressure in the chamber ≤ 50 mm. at. Art. Sealing cap furnace - heat bolt and bolt cutter c wicker sealing gasket. After loading the goods supplied in the muffle carburizer, the exhaust gas is discharged into the upper part of the muffle through the gate discharge (spark) for afterburning. Before and after the carburization process muffle is purged with nitrogen. Consumption carburizers 1 m² cemented surface averaging 0.35 ... 0.4 m³ / h for gas and 0.1 ... 0.12 l / h for liquid. The overlapping of the furnace circulation fan is installed with a diffuser of heat-resistant steel. Himself cap lifted by the actuator mounted on the trestle. The electric furnace system is equipped with automatic temperature control on the basis of solid-state relays and contactless microprocessor thermostat sets the temperature, time to treatment and stay in the mode. Heaters are placed on the tubes in the recesses of the side walls of the furnace hood. Modern energy-saving furnace lined with refractory and insulating materials. On the hearth is installed welded mesh of strips 50 × 10 m² 20H23N18 heat-resistant steel for mounting the cages (grid customer supplied). The height of the working space is measured from the upper surface of the lattice. The sides of the cages without openings. At a height less than the height of cages workspace Customer complements your batch to the height of the workspace solid (on the sides) metal box.
Write a review
Your Name:Your Review: Note: HTML is not translated!
Rating: Bad Good
Enter the code in the box below:
.
. 